Tripp Lite SV40KS2P3B uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA 36000 W

Tripp Lite SV40KS2P3B. UPS topology: Double-conversion (Online), Output power capacity: 40 kVA, Output power: 36000 W. Power plug: Terminal, Serial interface type: RS-232. Typical backup time at full load: 6.7 min, Typical backup time at half load: 15 min. Form factor: Tower, Product color: Black, Housing material: Steel. Width: 4.21" (106.9 mm), Depth: 30.2" (766.8 mm), Height: 58.1" (1475 mm)
Manufacturer: Tripp Lite
SKU: 5070554
Manufacturer part number: SV40KS2P3B
MSRP: $48,664.80
$34,323.25
The SV40KS2P3B SmartOnline® SV Series 40kVA Small-Frame 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system with a high 0.9 power factor is ideal for protecting a variety of critical IT systems.

The SV40KS2P3B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS), two 20kVA SV20PM power modules and three SVBM battery modules. Space is included for one additional user-installable SV20PM power module. External ±120VDC battery options, such as BP240V370, are also available from Tripp Lite for even more extended runtime.

The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.

With up to 92% efficiency in standard mode and up to 98% efficiency in optional economy mode, this 40kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front-panel display offers full UPS condition and status reporting.

40kVA 36kW 3-Phase Small-Chassis UPS System
- Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring
- Dual hardwire input design enables operation from up to 2 power sources
- Network-grade sine-wave AC output with 1% output voltage regulation and less than 2% output total harmonic distortion
- Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards
- High 0.9 power factor offers higher kW output than lower-rated competing legacy designs

Pre-Installed WEBCARDLX Network Interface
- Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH
- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
- Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status
- No Java required

Modular, Scalable Design for Maximum Flexibility
- Modular configuration with hot-swappable power and battery modules enables easy, fast maintenance with zero downtime
- Open slot for 1 additional 20kVA SV20PM power module accommodates increased capacity up to 60kVA (or 40kVA with N+1 fault tolerance)
- Open slot for 1 additional SVBM internal battery for extended runtime
External battery pack options available for even more extended runtime

Optional Economy Mode
- Up to 98% efficiency in optional economy mode to lower operating and cooling costs

Wide Input/Narrow Output Voltage Operating Range
- Enables full continuous online operation during brownouts as low as 121V and overvoltages up to 253V
- Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion mode

Advanced IGBT Inverter with Digital Signal Processor (DSP) Technology
- Provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacity

Automatic and Manual Bypass Options
- Keep connected equipment operational during routine maintenance or critical power module failure
The SV40KS2P3B SmartOnline® SV Series 40kVA Small-Frame 3-Phase On-Line Double-Conversion UPS System delivers true scalability and offers the highest level of secure, uninterrupted power protection. Featuring a modular, scalable design with high-efficiency voltage and frequency independent (VFI) operation, this on-line UPS system with a high 0.9 power factor is ideal for protecting a variety of critical IT systems.

The SV40KS2P3B includes pre-installed input, bypass and output breakers, as well as a static transfer switch (STS), two 20kVA SV20PM power modules and three SVBM battery modules. Space is included for one additional user-installable SV20PM power module. External ±120VDC battery options, such as BP240V370, are also available from Tripp Lite for even more extended runtime.

The Java-free HTML5-based WEBCARDLX interface enables full remote access for site power and UPS status monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network.

With up to 92% efficiency in standard mode and up to 98% efficiency in optional economy mode, this 40kVA UPS system helps you reduce operating and cooling costs. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure. Front-panel display offers full UPS condition and status reporting.

40kVA 36kW 3-Phase Small-Chassis UPS System
- Supports 208/120V or 220/127V AC 50/60Hz Wye 4-wire plus Earth hardwire input and output wiring
- Dual hardwire input design enables operation from up to 2 power sources
- Network-grade sine-wave AC output with 1% output voltage regulation and less than 2% output total harmonic distortion
- Tested to UL 1778 (U.S.), CSA (Canada) and NOM (Mexico) standards
- High 0.9 power factor offers higher kW output than lower-rated competing legacy designs

Pre-Installed WEBCARDLX Network Interface
- Allows full remote access for power monitoring, configuration, control and email notifications via secure web browser, SNMP, telnet or SSH
- Supports 10/100 Mbps auto-sensing for communication with an Ethernet network
- Optional EnviroSense2 sensors (sold separately) enable site monitoring of temperature, humidity and contact-closure status
- No Java required

Modular, Scalable Design for Maximum Flexibility
- Modular configuration with hot-swappable power and battery modules enables easy, fast maintenance with zero downtime
- Open slot for 1 additional 20kVA SV20PM power module accommodates increased capacity up to 60kVA (or 40kVA with N+1 fault tolerance)
- Open slot for 1 additional SVBM internal battery for extended runtime
External battery pack options available for even more extended runtime

Optional Economy Mode
- Up to 98% efficiency in optional economy mode to lower operating and cooling costs

Wide Input/Narrow Output Voltage Operating Range
- Enables full continuous online operation during brownouts as low as 121V and overvoltages up to 253V
- Regulates output voltage within 1% of the selected nominal output voltage in on-line double-conversion mode

Advanced IGBT Inverter with Digital Signal Processor (DSP) Technology
- Provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing and prevent the need to oversize generator systems relative to UPS capacity

Automatic and Manual Bypass Options
- Keep connected equipment operational during routine maintenance or critical power module failure
Products specifications
Attribute nameAttribute value
Country of OriginChina
Width4.21"
Depth30.2"
Height58.1"
Housing MaterialSteel
Input Frequency40 - 70 Hz
Display TypeLCD
Power factor0.9
UPS topologyDouble-conversion (Online)
Master (outer) case weight76.9 lbs
Master (outer) case length34.3"
Master (outer) case width11.6"
Master (outer) case height9.84"
Number of input phases3
Crest factor3:1
Number of output phases3
Efficiency (ECO mode)98 %
Total Harmonic Distortion (THD) (linear load)3 %
Weight570.1 lbs
Response Time0 ms
Emergency Power Off (EPO)Yes
Serial interfaceYes
EMI/RFI noise filteringYes
Cold startYes
Socket circuit breakerYes
Compliance certificatesRoHS
Technical details
Product colorBlack
Sustainability certificatesRoHS
Serial interface typeRS-232
Packaging data
Package width11.6"
Package depth34.3"
Package height64.8"
Package weight570.1 lbs
Ports & interfaces
Power plugTerminal
Design
Form factorTower
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-15 - 60 °C
Operating relative humidity (H-H)0 - 95 %
Operating altitude0 - 39370.1"
Power
Maximum current313.7 A
Output power capacity40 kVA
Features
Cooling typeActive
Output power36000 W
Noise level73 dB
Surge energy rating2496 J
Input operation voltage (min)120 V
Input operation voltage (max)220 V
Output operation voltage (min)120 V
Output operation voltage (max)220 V
WaveformPure sine
Built-in fanYes
Packaging content
Cables includedSerial
ManualYes
Logistics data
Quantity per master (outer) case1 pc(s)
Battery
Typical backup time at full load6.7 min
Typical backup time at half load15 min
Hot-swap batteryYes
Product tags
  • (80699)