Tripp Lite S3M80K uninterruptible power supply (UPS) Double-conversion (Online) 80 kVA 80000 W

Tripp Lite S3M80K. UPS topology: Double-conversion (Online), Output power capacity: 80 kVA, Output power: 80000 W. AC outlet types: Hardwire, Power plug: Hardwire. Form factor: Tower, Product color: Black, Housing material: Steel. Width: 23.6" (599.9 mm), Depth: 33.5" (849.9 mm), Height: 63" (1599.9 mm). Cables included: RS-232, USB cable
Manufacturer: Tripp Lite
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 6084751
Manufacturer part number: S3M80K
MSRP: $46,562.40
$31,825.65
Battery Backup and VFI Operation Protect Critical Loads The SmartOnline® S3M80K IGBT UPS supports the continuous availability of your most important operational and IT equipment loads through all power conditions, providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage- and frequency-independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 80kVA/kW of clean, continuous power, this 3-phase UPS system is ideally suited for critical applications in banking, education, healthcare, government and manufacturing sectors. Best-in-Class Footprint for Easy Integration into Your Network Application The UPS market’s smallest footprint for 3-phase 208V systems lets you install the S3M80K in spaces that would otherwise have required expensive retrofitting. By achieving its compact size without compromising runtime, reliability or functionality, the S3M80K is recommended for data centers, colocation facilities and edge computing environments that require high efficiency, high performance and clean, reliable power protection, while preserving as much space as possible for revenue-generating server racks. Efficient Operation and Design Reduces Cost of Ownership ENERGY STAR 2.0-certified technology provides high operational efficiency to save on utility and cooling costs, as well as protect the environment. This UPS achieves up to 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. Unity output power factor (1.0) lets you support more equipment. A low THDi (<3%) improves generator compatibility. A low THDv (≤2%) and active power factor correction with DSP control improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Automatic and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime. External Batteries Supply Reliable Backup with Expandable Runtime Options The S3M80K uses external battery cabinets, including BP240V65L and BP240V100L (sold separately), to provide backup support in case of a power failure. These cabinets are available with or without internal batteries. No internal batteries are included with the S3M80K. A one-touch cold-start button powers up the UPS with battery power only. Intuitive LCD Interface Delivers Important Performance Information at a Glance The large five-inch touchscreen LCD panel displays critical operating conditions and diagnostic data, including battery and load status. Four LEDs provide information about AC, bypass, battery and fault status. Remote Network Monitoring and Control Available 24 Hours a Day The optional Java-free WEBCARDLXMINI network management card (sold separately) enables remote management through embedded HTML5 web, SSH/telnet and SNMP interfaces, as well as integration with a wide range of network management systems and DCIM platforms. WEBCARDLXMINI also supports EnviroSense2 (sold separately), which monitors temperature, humidity and other environmental factors. Three MODBUS ports (RS-485, USB, RS-232) may also be used to monitor and manage the UPS. A Remote Emergency Power Off (REPO) port allows shutdown from a safe distance during emergencies. Parallel Capability Provides Additional Capacity Connect up to six S3M80K units in parallel using separate/shared battery cabinets for 480kVA maximum capacity or N+N fault tolerance redundancy.
Battery Backup and VFI Operation Protect Critical Loads The SmartOnline® S3M80K IGBT UPS supports the continuous availability of your most important operational and IT equipment loads through all power conditions, providing a compact backup power platform that’s easy to manage and inexpensive to operate. Sophisticated voltage- and frequency-independent (VFI) operation and advanced IGBT rectifier technology with DSP control deliver reliable output power quality. Providing up to 80kVA/kW of clean, continuous power, this 3-phase UPS system is ideally suited for critical applications in banking, education, healthcare, government and manufacturing sectors. Best-in-Class Footprint for Easy Integration into Your Network Application The UPS market’s smallest footprint for 3-phase 208V systems lets you install the S3M80K in spaces that would otherwise have required expensive retrofitting. By achieving its compact size without compromising runtime, reliability or functionality, the S3M80K is recommended for data centers, colocation facilities and edge computing environments that require high efficiency, high performance and clean, reliable power protection, while preserving as much space as possible for revenue-generating server racks. Efficient Operation and Design Reduces Cost of Ownership ENERGY STAR 2.0-certified technology provides high operational efficiency to save on utility and cooling costs, as well as protect the environment. This UPS achieves up to 94% efficiency in double-conversion mode and up to 98% in ECO mode, reducing your power and cooling costs. Unity output power factor (1.0) lets you support more equipment. A low THDi (<3%) improves generator compatibility. A low THDv (≤2%) and active power factor correction with DSP control improve output performance. The hardware and firmware platform design reduces the number of unique boards, improving mean time to repair (MTTR) and resulting in reduced downtime. Automatic and maintenance bypass transfer UPS load to utility power during faults, overloads and maintenance, which also avoids costly system downtime. External Batteries Supply Reliable Backup with Expandable Runtime Options The S3M80K uses external battery cabinets, including BP240V65L and BP240V100L (sold separately), to provide backup support in case of a power failure. These cabinets are available with or without internal batteries. No internal batteries are included with the S3M80K. A one-touch cold-start button powers up the UPS with battery power only. Intuitive LCD Interface Delivers Important Performance Information at a Glance The large five-inch touchscreen LCD panel displays critical operating conditions and diagnostic data, including battery and load status. Four LEDs provide information about AC, bypass, battery and fault status. Remote Network Monitoring and Control Available 24 Hours a Day The optional Java-free WEBCARDLXMINI network management card (sold separately) enables remote management through embedded HTML5 web, SSH/telnet and SNMP interfaces, as well as integration with a wide range of network management systems and DCIM platforms. WEBCARDLXMINI also supports EnviroSense2 (sold separately), which monitors temperature, humidity and other environmental factors. Three MODBUS ports (RS-485, USB, RS-232) may also be used to monitor and manage the UPS. A Remote Emergency Power Off (REPO) port allows shutdown from a safe distance during emergencies. Parallel Capability Provides Additional Capacity Connect up to six S3M80K units in parallel using separate/shared battery cabinets for 480kVA maximum capacity or N+N fault tolerance redundancy.
Products specifications
Attribute name Attribute value
Weight 624.3 lbs
Master (outer) case weight 701.7 lbs
Master (outer) case height 70.3"
Output voltage regulation ±1 %
Efficiency (ECO mode) 98.5 %
Height 63"
Input current Total Harmonic Distortion (THD) 3 %
Input power factor 0.99
Master (outer) case length 38"
Number of input phases 3
Number of output phases 3
Packaging data
Package height 70.3"
Package weight 701.7 lbs
Package depth 38"
Ports & interfaces
AC outlet types Hardwire
Operational conditions
Operating altitude 0 - 39370.1"
Power
Maximum current 400 A
Output power capacity 80 kVA
Features
Output power 80000 W
Noise level 73.9 dB
Input operation voltage (max) 220 V
Output operation voltage (max) 220 V
Efficiency 93 %
Output voltage Total Harmonic Distortion (THD) 3 %