Tripp Lite PDUMVR30NETLX power distribution unit (PDU) 24 AC outlet(s) 0U Black

Tripp Lite PDUMVR30NETLX. PDU types: Switched, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: NEMA L5-20R, Power plug: NEMA L5-30P. Cable length: 120.1" (3.05 m), Certification: UL60950-1: 2007 R12.11 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011 (Canada) FCC CLASS A PART 15.... Monitoring: Power, Outlet control: Lock-out, Recycle, Turn off, Turn on, Supported network protocols: IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP. Nominal input voltage: 100-127 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz
Manufacturer: Tripp Lite
Availability: In stock
SKU: 5084526
Manufacturer part number: PDUMVR30NETLX
MSRP: $1,974.96
$1,392.94
The PDUMVR30NETLX 2.9kW Single-Phase Switched PDU with individual outlet metering provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. The switched PDU features 24 individually controllable NEMA 5-15/20R outlets with included cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-foot power cord with NEMA L5-30P plug connects the PDU to an AC source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A digital ammeter allows you to monitor each load bank’s current, each outlet’s current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The switched PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets.
Distributes, Monitors and Manages Network-Grade AC Power - 2.9kW 120V switched PDU with single-phase input - NEMA L5-30P plug with 10 ft. cord connects to compatible AC power source - Firmware upgrades support future product enhancements 24 Switched NEMA 5-15/20R Outlets Distribute AC Power - Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices - Included cord retention brackets prevent cables from becoming accidentally disconnected Digital Ammeter - Reports current for each load bank, each individual outlet, and total PDU load - Supports IP-address self-ID - Digits flip 180° for easy reading at either angle Built-In LX Platform Interface - Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH - Supports 10/100 Mbps auto-sensing for communication with an Ethernet network - Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities - No Java required Broad Communications Compatibility - Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP - Supports automatic and manual assignment of IP address Essential Safety Features - Tiered access allows administrator and guest to log in via web browser - Immediate alert notifications via email or SNMP traps - Supports user-specified alarm notification thresholds - Real-time clock backup maintains day/date even if PDU is unpowered Easy 0U Installation in EIA-Standard 19 in. Racks - 70 in. PDU mounts vertically using included toolless buttons or rack-mounting brackets - Included PDUMVROTATEBRKT allows mounting with rear-facing outlets TAA-Compliant - Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
The PDUMVR30NETLX 2.9kW Single-Phase Switched PDU with individual outlet metering provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. By reducing the frequency of on-site visits, these advanced remote capabilities can save you money and reduce downtime. The switched PDU features 24 individually controllable NEMA 5-15/20R outlets with included cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-foot power cord with NEMA L5-30P plug connects the PDU to an AC source, generator or protected UPS. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. A digital ammeter allows you to monitor each load bank’s current, each outlet’s current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The switched PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets.
Distributes, Monitors and Manages Network-Grade AC Power - 2.9kW 120V switched PDU with single-phase input - NEMA L5-30P plug with 10 ft. cord connects to compatible AC power source - Firmware upgrades support future product enhancements 24 Switched NEMA 5-15/20R Outlets Distribute AC Power - Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices - Included cord retention brackets prevent cables from becoming accidentally disconnected Digital Ammeter - Reports current for each load bank, each individual outlet, and total PDU load - Supports IP-address self-ID - Digits flip 180° for easy reading at either angle Built-In LX Platform Interface - Allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH - Supports 10/100 Mbps auto-sensing for communication with an Ethernet network - Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities - No Java required Broad Communications Compatibility - Supports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP - Supports automatic and manual assignment of IP address Essential Safety Features - Tiered access allows administrator and guest to log in via web browser - Immediate alert notifications via email or SNMP traps - Supports user-specified alarm notification thresholds - Real-time clock backup maintains day/date even if PDU is unpowered Easy 0U Installation in EIA-Standard 19 in. Racks - 70 in. PDU mounts vertically using included toolless buttons or rack-mounting brackets - Included PDUMVROTATEBRKT allows mounting with rear-facing outlets TAA-Compliant - Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Products specifications
Attribute nameAttribute value
Depth2.05"
Height70"
Weight9.94 lbs
Outlet controlLock-out, Recycle, Turn off, Turn on
MonitoringPower
Master AC outlets quantity24
Packaging data
Package depth76.1"
Package height5.4"
Ports & interfaces
AC outlet typesNEMA L5-20R
Design
CertificationUL60950-1: 2007 R12.11 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011 (Canada) FCC CLASS A PART 15 (Emissions) NOM (Mexico) TAA Compliant
Operational conditions
Operating temperature (T-T)5 - 122 °F
Power
Maximum power2900 W
Weight & dimensions
Dimensions (WxDxH)2.2 x 2.05 x 70.1"
Other features
Nominal output voltage100-127 V
Package dimensions (WxDxH)6.1 x 75.8 x 4.49"
Protocols
Supported network protocolsIPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP