Tripp Lite PDUMV20HV-36 power distribution unit (PDU) 20 AC outlet(s) 0U Black
Tripp Lite PDUMV20HV-36. PDU types: Metered, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 20 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: NEMA L6-20P. Cable length: 120.1" (3.05 m). Monitoring: Current. Nominal input voltage: 200 - 240 V, Maximum current: 20 A, Nominal output voltage: 200 - 240 V
SKU: 6058332
Manufacturer part number: PDUMV20HV-36
MSRP: $357.56
$252.19
Single-Phase PDU Distributes and Monitors Network-Grade Power in Real Time This local metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMV20HV-36 features 16 C13 and four C19 208/230V outlets for connecting equipment. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged. The switchless design helps prevent an accidental shutdown, which could lead to costly downtime.
Digital Load Meter Helps Prevent Potentially Expensive Overloads A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low.
Versatile Installation Options Give You Plenty of Choices The 40-inch 0U PDU mounts vertically in an EIA-standard 19-inch rack using the included toolless mounting buttons or the included mounting brackets with user-supplied hardware. You may also use the brackets to secure the PDU to the underside of a counter with the addition of two user-supplied screws. Bolt-down retention brackets keep power cords organized and your rack free of clutter.
Compatible with a Variety of Input Cords to Fit Your Facility’s Power Source The PDU’s C20 inlet accepts a variety of 16A international cordsets. An included 10-ft. (3.05 m) cord with NEMA L6-20P input plug connects to an AC power source, generator or protected UPS system to distribute power to connected loads.
- 16 C13 and 4 C19 208/230V outlets distribute AC power to connected equipment
- Digital ammeter for on-site real-time load monitoring helps prevent power overloads
- Switchless design helps prevent accidental shutdowns that can lead to costly downtime
- 10-ft. (3.05 m) detachable cord with L6-20P single-phase input connects to AC power source
- 40 in. 0U PDU with included mounting brackets installs in rack or under counter