Tripp Lite PDUMH30AT power distribution unit (PDU) 25 AC outlet(s) 2U Black

Tripp Lite PDUMH30AT. PDU types: Metered, Rack capacity: 2U, Mounting: Horizontal. AC outlets quantity: 25 AC outlet(s), AC outlet types: NEMA 5–15,NEMA 5–20R,NEMA L5-30R, Power plug: NEMA L5-30P. Cable length: 118.1" (3 m), Certification: UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico). Nominal input voltage: 100-127 V, Maximum current: 30 A, AC input frequency: 60 Hz. Width: 17.3" (439.9 mm), Depth: 11.9" (302 mm), Dimensions (WxDxH): 17.3 x 11.9 x 3.41" (440 x 302 x 86.6 mm)
Manufacturer: Tripp Lite
Availability: In stock
SKU: 3016123
Manufacturer part number: PDUMH30AT
MSRP: $1,125.08
$793.52
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. - 120V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous) - Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord - Visual meter reports output amp and kW power consumption, plus input voltage - 2U horizontal rackmount form factor; 11.9 in. / 30.2 cm depth - 25 outlets (24 5-15/20R, 1 L5-30R) - Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable - Highly reliable solid-state switching enables fast 1-5 millisecond transfer between primary and secondary inputs - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - Front panel LEDs confirm power availability on both input lines - TAA Compliant Version Available - Order Tripp Lite PDUMH30ATAA
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. - 120V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous) - Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord - Visual meter reports output amp and kW power consumption, plus input voltage - 2U horizontal rackmount form factor; 11.9 in. / 30.2 cm depth - 25 outlets (24 5-15/20R, 1 L5-30R) - Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable - Highly reliable solid-state switching enables fast 1-5 millisecond transfer between primary and secondary inputs - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source - Front panel LEDs confirm power availability on both input lines - TAA Compliant Version Available - Order Tripp Lite PDUMH30ATAA
Products specifications
Attribute nameAttribute value
Packaging data
Package depth17.1"
Package height8.07"
Package weight17.5 lbs
Ports & interfaces
AC outlets quantity25 AC outlet(s)
AC outlet typesNEMA 5–15,NEMA 5–20R,NEMA L5-30R
Design
CertificationUL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico)
Weight & dimensions
Dimensions (WxDxH)17.3 x 11.9 x 3.41"
Other features
Nominal output voltage100-127 V