Server Technology C2W54CE power distribution unit (PDU) 54 AC outlet(s) 0U Black
Server Technology C2W54CE. PDU types: Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 54 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC 60309. Monitoring: Humidity, Temperature. Nominal input voltage: 208 V, Maximum current: 60 A, AC input frequency: 50/60 Hz. Width: 2.2" (56 mm), Depth: 3.03" (77 mm), Height: 80" (2032 mm)
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 4663921
Manufacturer part number: C2W54CE-DQME2M00
The Server Technology® PRO2 Smart/Switched POPS PDU provides control of outlet power(Switched only) and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output (POPS only). These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Smart/Switched POPS “Master" PDU can be connected to as many as three (with optional module) PRO2 Smart/Switched POPS “Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration. NETWORK MONITORING The PRO2 hot-swappable network card provides for HTTP(S), SSH, Telnet,SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more. HOT-SWAP NETWORK CARD Network access is ensured when power is lost to the Primary unit with backup power provided by the primary Expansion unit. STAR MULTI-LINKING PRO2 provides the ability to link up to four power circuits using one IP address. First Expansion provides backup power to network card. TEMPERATURE/ HUMIDITY MONITORING PRO2 Primary and Expansion units each support two external 10' (3m) T/H probes. Receive SNMP-based alerts and email notifications. AUTO-FLIP CURRENT DISPLAY Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets. PER-INLET POWER SENSING Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy. BRANCH CURRENT MONITORING PRO2 monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit. BRANCH CIRCUIT PROTECTION PRO2 meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses. ALTERNATING-PHASE OUTLETS 3-phase power is wired in an alternating fashion per outlet for simplified load balancing, reduced cord lengths, and better airflow. HIGH-DENSITY OUTLET TECHNOLOGY The highest outlet density available in a network connected PDU. Meets IEC C13 and C19 specifications, plus high native retention and UL94V-0 flame rating. HIGH RETENTION LOCKING OUTLETS PRO2 receptacles have high retention and are compatible with P-Lock type power cords. HIGH TEMPERATURE RATING This product has been tested and approved for safe and reliable operation in 60°C (140°F) data center environments. FLEXIBLE MOUNTING PRO2 includes standard button mounts along with provisions for custom mounting brackets (contact Server Technology for details). COLOR IDENTIFICATION Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black.