Raritan PX3-5660V-C1 power distribution unit (PDU) 30 AC outlet(s) 0U Black

Raritan PX3-5660V-C1. PDU types: Monitored, Switched, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 30 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, NEMA 5–20R, Power plug: IEC 320. Cable length: 118.1" (3 m), Security algorithms: HTTPS, SSH. Monitoring: Current, Power, Voltage. Nominal input voltage: 208 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz
Manufacturer: Raritan
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 6635292
Manufacturer part number: PX3-5660V-C1
$2,389.00
Monitored and switched rack power distribution unit (0U [vertical], 8.6kVA, 30 outlets). INPUT: 208v (3-phase WYE), 30a - NEMA L21-30P plug (4P5W); OUTPUT: 21@ C13, 6@ C19 outlets; on 3@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 65mm x 1780mm (2.1in x 2.6in x 70.1in). Max Weight 7 kg. Maximum ambient temperature 60C at full load.

 

  • Securelock
  • Removable Controller
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM
  • Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure
Monitored and switched rack power distribution unit (0U [vertical], 8.6kVA, 30 outlets). INPUT: 208v (3-phase WYE), 30a - NEMA L21-30P plug (4P5W); OUTPUT: 21@ C13, 6@ C19 outlets; on 3@ 2-pole, 20a Overcurrent Protectors; FEATURES: Billing-Grade (+/- 1%) Energy Metering [kW, kVA, V, A, Power Factor] - per inlet, per breaker/fuse, per outlet; Remote network monitoring via HTML, JSON-RPC, SSH, Telnet, MODBUS/TCP, and SNMPv3. Onboard embedded processor with minimum 536MHz clock speed, 16MB SPI Flash, and 64MB DDR2 RAM. Cascading upto 16 PDU's using single Ethernet or USB connection. Environmental monitoring [temp/humidity] capable – up to 32 sensors. Individual outlet numbers labeled on chassis. Automated deployment via TFTP, DHCP, SSH(CLI), or USB Flash Drives. WiFi Capable. USB Webcam Capable. iPad/iPhone/Android App. Dual 10/100/1000 Ethernet port. Tri-color status LED per receptacle. Breaker metering and alarming (0V detection). Max Dimensions 52mm x 65mm x 1780mm (2.1in x 2.6in x 70.1in). Max Weight 7 kg. Maximum ambient temperature 60C at full load.

 

  • Securelock
  • Removable Controller
  • Embedded Processor: ARM Cortex A5 500MHZ (Atmel A5D21C), 16MB SPI Flash, 128MB DDR2 RAM
  • Compatible Sensors: Temperature, Humidity, Air Flow, Differential Pressure, Water Leak, and Contact Closure
Products specifications
Attribute nameAttribute value
Load Capacity7900 VA
Height70.1"
Block 1 output current12 A
Block 2 output current16 A
Width2.05"
Depth2.56"
Weight15.4 lbs
MountingVertical
DisplayLCD
Cable Length118.1"
TypeThree-phase
MonitoringCurrent, Power, Voltage
Technical details
Product colorBlack
Packaging data
Package height80.9"
Package weight19.8 lbs
Package width11"
Package depth4.53"
Ports & interfaces
Power plugIEC 320
AC outlets quantity30 AC outlet(s)
AC outlet typesC13 coupler, C19 coupler, NEMA 5–20R
Ethernet LAN (RJ-45) ports3
USB ports quantity3
Design
PDU typesMonitored, Switched
Operational conditions
Storage relative humidity (H-H)0 - 100 %
Operating altitude0 - 72000"
Operating temperature (T-T)0 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)0 - 85 %
Non-operating altitude0 - 120000"
Power
Maximum current30 A
Nominal input voltage208 V
AC input frequency50 - 60 Hz
Power protection featuresOverload
Features
Output voltage100 - 208 V
Rack capacity0U
On/off switchY
Other features
Nominal output voltage120 V
Security
Security algorithmsHTTPS, SSH