HPE SN6630C Managed None 2U Gray

HPE SN6630C. Switch type: Managed. Basic switching RJ-45 Ethernet ports type: None. Rack mounting, Form factor: 2U
Manufacturer: HPE
SKU: 7586214
Manufacturer part number: R4D90A#05Y
$102,579.00
Are you looking to modernize your storage network? The all-flash data center and emerging NVMe storage requires a modern storage network that can keep up with pace of innovation seen with compute and storage resources. The HPE C-series SN6630C 96-port 32Gb Fibre Channel (FC) Switch is the next generation 96-port 2-rack unit FC switch that provides high-speed Fibre Channel connectivity in the SAN. This switch offers state-of-art analytics and telemetry capability built into its next-generation Application-Specific Integrated Circuit (ASIC) platform. The Non-Volatile Memory express (NVMe)-ready switch allows a seamless transition to Fibre Channel Non-Volatile Memory Express (FC-NVMe) workloads whenever available without any hardware upgrade in the SAN. This high-density, highly reliable, and scalable, enterprise-class switch is ideal for medium to large departmental SANs. Features High-speed Flash-ready Performance - HPE C-series SN6630C Fibre Channel Switch with centralized non-blocking arbitration, provides consistent 32 Gbps low-latency performance across traffic conditions for every Fibre Channel port on the switch. - Delivers increased performance with an aggregate bandwidth of 3 Tbps for growing and dynamic workloads. - It offers state-of-the-art SAN Insights (analytics) and telemetry capabilities that have been built into this next-generation hardware platform. - FC-NVMe-ready SAN switch with enhanced buffer-to-buffer (B2B) credits connecting both storage and host ports and FC link encryption. More Flexibility - HPE C-series SN6630C Fibre Channel Switch provides an option to deploy as few as 48 32-Gbps FC ports in the entry-level variant, and then grow in increments of 16 ports to up to 96 ports. This allows four possible configurations of 48, 64, 80, and 96 ports. - The 32 Gbps ports allow users to deploy them on existing 16 or 8 Gbps transceivers, reducing initial CapEx and investment protection with an option to upgrade to 32 Gbps transceivers and adapters whenever needed. - Increased fabric scalability provides more flexibility for a variety of SAN architectures. Easy Manageability - HPE C-series SN6630C Fibre Channel Switch supports enhanced diagnostic features such as inter-switch link (ISL) and host-bus-adapter (HBA) diagnostics, read diagnostic parameters, link cable beacon, and advanced reliability features such as forward error correction (FEC) with HBA ports. - Cisco Data Center Network Manager Essentials Edition software, included with the switch, provides a centralized management tool with task-based wizards that simplifies management of switches and fabrics. Additional advanced features are available with the DCNM licensed version, sold separately. - Cisco SAN Insights delivers deep visibility into I/O traffic between the compute and the storage infrastructure. This information is in addition to the already-available visibility obtained from individual ports, switches, servers, virtual machines, and storage arrays. Intelligent Network Services for SAN - HPE C-series SN6630C Fibre Channel Switch supports slow-drain detection and isolation, virtual SAN (vSAN) technology, access control lists for hardware-based intelligent frame processing, smart zoning, and other various services. - Provides visibility into all virtual machines that are accessing the storage LUNs in the fabric and offers an end-to-end view for analytics. - Delivers powerful representational state transfer (REST) and NX-API capabilities to enable flexible and rapid programming of utilities for the SAN.
Are you looking to modernize your storage network? The all-flash data center and emerging NVMe storage requires a modern storage network that can keep up with pace of innovation seen with compute and storage resources. The HPE C-series SN6630C 96-port 32Gb Fibre Channel (FC) Switch is the next generation 96-port 2-rack unit FC switch that provides high-speed Fibre Channel connectivity in the SAN. This switch offers state-of-art analytics and telemetry capability built into its next-generation Application-Specific Integrated Circuit (ASIC) platform. The Non-Volatile Memory express (NVMe)-ready switch allows a seamless transition to Fibre Channel Non-Volatile Memory Express (FC-NVMe) workloads whenever available without any hardware upgrade in the SAN. This high-density, highly reliable, and scalable, enterprise-class switch is ideal for medium to large departmental SANs. Features High-speed Flash-ready Performance - HPE C-series SN6630C Fibre Channel Switch with centralized non-blocking arbitration, provides consistent 32 Gbps low-latency performance across traffic conditions for every Fibre Channel port on the switch. - Delivers increased performance with an aggregate bandwidth of 3 Tbps for growing and dynamic workloads. - It offers state-of-the-art SAN Insights (analytics) and telemetry capabilities that have been built into this next-generation hardware platform. - FC-NVMe-ready SAN switch with enhanced buffer-to-buffer (B2B) credits connecting both storage and host ports and FC link encryption. More Flexibility - HPE C-series SN6630C Fibre Channel Switch provides an option to deploy as few as 48 32-Gbps FC ports in the entry-level variant, and then grow in increments of 16 ports to up to 96 ports. This allows four possible configurations of 48, 64, 80, and 96 ports. - The 32 Gbps ports allow users to deploy them on existing 16 or 8 Gbps transceivers, reducing initial CapEx and investment protection with an option to upgrade to 32 Gbps transceivers and adapters whenever needed. - Increased fabric scalability provides more flexibility for a variety of SAN architectures. Easy Manageability - HPE C-series SN6630C Fibre Channel Switch supports enhanced diagnostic features such as inter-switch link (ISL) and host-bus-adapter (HBA) diagnostics, read diagnostic parameters, link cable beacon, and advanced reliability features such as forward error correction (FEC) with HBA ports. - Cisco Data Center Network Manager Essentials Edition software, included with the switch, provides a centralized management tool with task-based wizards that simplifies management of switches and fabrics. Additional advanced features are available with the DCNM licensed version, sold separately. - Cisco SAN Insights delivers deep visibility into I/O traffic between the compute and the storage infrastructure. This information is in addition to the already-available visibility obtained from individual ports, switches, servers, virtual machines, and storage arrays. Intelligent Network Services for SAN - HPE C-series SN6630C Fibre Channel Switch supports slow-drain detection and isolation, virtual SAN (vSAN) technology, access control lists for hardware-based intelligent frame processing, smart zoning, and other various services. - Provides visibility into all virtual machines that are accessing the storage LUNs in the fabric and offers an end-to-end view for analytics. - Delivers powerful representational state transfer (REST) and NX-API capabilities to enable flexible and rapid programming of utilities for the SAN.
Products specifications
Attribute nameAttribute value
SFP module slots quantity96
Width17.4"
Depth22.3"
Height3.39"
Weight41.7 lbs
Switch TypeManaged
Power supply includedY
Access Control List (ACL)Y
SSH/SSL supportY
Authentication typeRADIUS
Technical details
Product colorGray
Ports & interfaces
Basic switching RJ-45 Ethernet ports typeNone
Design
Form factor2U
Operational conditions
Operating temperature (T-T)0 - 40 °C
Storage temperature (T-T)-40 - 70 °C
Operating relative humidity (H-H)10 - 90 %
Power
AC input frequency50 - 60 Hz
Number of power supply units2
Redundant power supply (RPS) supportY
Other features
Rack mountingY
Performance
Fiber optic connectorSFP
Fiber ports quantity48
Network
Cable types supportedFiber
Quality of Service (QoS) supportY
Power over Ethernet (PoE)
Power over Ethernet (PoE)N
Security
Security algorithms256-bit AES
Protocols
Management protocolsSNMP 1, SNMP 3, SMI-S, SSH-2, CLI