APC Smart-UPS 3000VA LCD RM 2U 120V with Network Card Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Audible alarms Provides notification of changing utility power and UPS power conditions Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance Boost and Trim Automatic Voltage Regulation (AVR) Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress. Disconnected battery notification Warns when a battery is not available to provide backup power. Energy meter Provides actual kilowatt hours of usage for energy conscious users. Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Intuitive LCD interface Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. LED Indicators Provide easy-to-read status of the unit and utility power conditions. Network manageable Provides remote power management of the UPS over the network. Outlet group control Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups). Predictive replace battery date Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. Pure sine wave output on battery Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. Sequenced network shutdown and reboot Customize network shutdown and reboot sequence of connected servers and UPSs. Serial connectivity Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks. Single switched outlet group Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. USB connectivity Provides management of the UPS via a USB port (not available on all models).
Manageability LED status indicators Quickly understand unit and power status with visual indicators. Serial connectivity Provides management of the UPS via a serial port. USB connectivity Provides management of the UPS via a USB port (not available on all models). Disconnected battery notification Warns when a battery is not available to provide backup power. Audible alarms Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition. Network manageable Provides remote power management of the UPS over the network.
Marketing Features Peace of mind that comes with full equipment compatibility and reliability of a leader Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards. Avoids costly power problems by keeping your IT equipment and data safe and available Network grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systems Save time with easy and convenient remote accessibility Network manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities. Smarter productivity with ability to tailor to your specific application needs Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications. Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management Patented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.
Availability Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Disconnected battery notification Warns when a battery is not available to provide backup power. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Adaptability Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Serviceability Resettable circuit breakers Enables a quick recovery from overload events. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced Predictive failure notification Provides early-warning fault analysis ensuring proactive component replacement.
Safety Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.