APC APDU10450SM power distribution unit (PDU) 42 AC outlet(s) 0U Black

APC APDU10450SM. PDU types: Metered, Rack capacity: 0U, Type: Three-phase. AC outlets quantity: 42 AC outlet(s), AC outlet types: C13 coupler, C15 coupler, C19 coupler, C21 coupler. Cable length: 70.9" (1.8 m), Certification: UL 62368-1 CSA C22.2 No 62368-1 FCC part 15 subpart B CE EN 62368-1. Nominal input voltage: 200 - 240, 346 - 415 V, Maximum current: 60 A, AC input frequency: 50 - 60 Hz. Width: 0.22" (5.6 mm), Depth: 0.295" (7.5 mm), Height: 7.19" (182.6 mm)
Manufacturer: APC
Availability: Out of Stock - on backorder and will be dispatched once in stock.
SKU: 6571059
Manufacturer part number: APDU10450SM
MSRP: $6,650.00
$5,063.25
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. Outlet and PDU level power metering for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Products specifications
Attribute nameAttribute value
Width0.22"
Depth0.295"
Height7.19"
Weight28 lbs
MountingVertical
Cable Length70.9"
TypeThree-phase
Number of phases3
Technical details
Product colorBlack
Packaging data
Package height78"
Package weight34.6 lbs
Package depth10.3"
Package width5.2"
Ports & interfaces
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
AC outlets quantity42 AC outlet(s)
Design
CertificationUL 62368-1 CSA C22.2 No 62368-1 FCC part 15 subpart B CE EN 62368-1
PDU typesMetered
Operational conditions
Operating temperature (T-T)23 - 140 °F
Non-operating altitude0 - 600000"
Storage temperature (T-T)-25 - 65 °C
Operating relative humidity (H-H)5 - 95 %
Storage relative humidity (H-H)5 - 95 %
Operating altitude0 - 120000"
Power
Nominal input voltage200 - 240, 346 - 415 V
Maximum current60 A
AC input frequency50 - 60 Hz
Features
Rack capacity0U